Schreiber-chillers 30AC User Manual

Browse online or download User Manual for Equipment Schreiber-chillers 30AC. Schreiber Chillers 30AC User Manual [en]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 18
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
I
I
N
N
S
S
T
T
A
A
L
L
L
L
A
A
T
T
I
I
O
O
N
N
,
,
O
O
P
P
E
E
R
R
A
A
T
T
I
I
O
O
N
N
&
&
M
M
A
A
I
I
N
N
T
T
E
E
N
N
A
A
N
N
C
C
E
E
O
O
W
W
N
N
E
E
R
R
S
S
M
M
A
A
N
N
U
U
A
A
L
L
Model:
30AC
Voltage:
220/1
Ref. Charge:
R134A
Tel: (562) 926-3855
Fax: (562) 926-0969
Page view 0
1 2 3 4 5 6 ... 17 18

Summary of Contents

Page 1 - Fax: (562) 926-0969

IINNSSTTAALLLLAATTIIOONN,, OOPPEERRAATTIIOONN && MMAAIINNTTEENNAANNCCEE OOWWNNEERRSS MMAANNUUAALL Model: 30AC Voltage: 220/1 Ref. Ch

Page 2 - TABLE OF CONTENTS

SERVICE BULLETIN HERMETIC COMPRESSOR ELECTRICAL TERMINAL VENTING CAN BE DANGEROUS ****** When the insulating material, which supports a hermetic comp

Page 3 - 30AC Specifications:

on Tecumseh Products Company drawings and diagrams using the parts as shown on Tecumseh Products Company bills of material. Hermetic compressors can

Page 4 - STARTUP CHECKLIST

point if the leads are not properly removed, which can result in the terminal venting and hot oil discharging. No ignition, however, can occur if all

Page 5 - Model 30 AC – 230/1

protective device until you have located and corrected the problem. Refer to the Unit Wiring Diagram and Service Manual for the proper procedure and w

Page 6 - OPERATION

TROUBLE SHOOTING - PART I SYMPTOM DIAGNOSIS REMEDY Compressor won't run Check Power supply Electrical circuit Check Line loa

Page 7 - Electrical System:

TROUBLE SHOOTING - PART II REFRIGERATION SYSTEM INTERNAL PRESSURE USING REFRIGERANT R-134A * High Pressure Switch : Manual Reset - Cut out at 42

Page 8 - Chilled Water System

30AC – 230/1 If this unit has special feature(s) installed, see appendix for part number(s). Part Number Description 115/1 230/1 Qty. Refrigeratio

Page 10 - SERVICE BULLETIN

(562) 926-3855 Schreiber Limited Warranty Schreiber warrants the product described herein against defective material or workmanship for one year

Page 11

TABLE OF CONTENTS Model ………………………………….……………………………….………………………….. 1 Caution ………………………………….…………………………….…………………………... 2 30AC Specifications …

Page 12

30AC Specifications: GENERAL Max rated ambient temp. 95 °F Min. Chilled water temp. 44 °F Max Water Temp. 85 °F REFRIGERATION Refrigerant R134A Char

Page 13 - MAINTENANCE INFORMATION

STARTUP CHECKLIST • POWER SUPPLY: Verify that the power you are supplying to the chiller matches the requirements as stated on the nameplate. Hookin

Page 14 - TROUBLE SHOOTING - PART I

Schreiber Engineering – Air Cooled Water Chiller Model 30 AC – 230/1 This unit comes completely wired for 230/1. To test unit as follows. NOTE: Ma

Page 15 - TROUBLE SHOOTING - PART II

INSTALLATION 1. Place chiller on level ground. 2. Allow 3 of clearance in front of the air inlet and outlet. If the airflow in and out of the chil

Page 16

Set point adjustment Set point view button INSIDE YOUR CHILLER Electrical System: • This chiller runs off of 220/1 Volt, single-phase power. It

Page 17

Refrigeration System • The refrigeration system is factory charged with R-134A. If the refrigeration system has to be serviced and recharged with re

Page 18 - Schreiber Limited Warranty

SPECIAL FEATURES FOR MODEL 30AC Chilled Water Filter This unit has a 3/8" clear filter housing with a 3/8" - (5M) cartridge. There is an e